{"id":2138,"date":"2020-05-20T06:47:01","date_gmt":"2020-05-20T06:47:01","guid":{"rendered":"http:\/\/cybercom-software.com\/blog\/?p=2138"},"modified":"2020-05-21T01:55:45","modified_gmt":"2020-05-21T01:55:45","slug":"connecting-to-the-phonepad-5-server","status":"publish","type":"post","link":"https:\/\/cybercom-software.com\/blog\/connecting-to-the-phonepad-5-server\/","title":{"rendered":"Connecting to the PhonePad 5 Server."},"content":{"rendered":"<p>One of the great things about PhonePad is that you don&#8217;t need to configure the workstation software to connect to the PhonePad Server.\u00c2\u00a0 It does it all automatically using Server Auto-Discovery.<\/p>\n<p>When you start PhonePad, your PhonePad workstation software will send out a message asking if there are any PhonePad servers on the network.\u00c2\u00a0 The server will respond with its connection details, which the workstation will use to establish a connection.<\/p>\n<p>Here&#8217;s an example of that happening.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery.png\"><img data-opt-id=1304226314  fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-2139\" src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery.png\" alt=\"log phone messages\" width=\"505\" height=\"382\" srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:505\/h:382\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery.png 505w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:227\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery.png 300w\" sizes=\"(max-width: 505px) 100vw, 505px\" \/><\/a>If you find that PhonePad is unable to locate a server, or if you get an error message similar to this then something may be blocking the UDP protocol on your Server, workstation, or network.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Unable-to-Initialise-Server-Auto-Discovery.png\"><img data-opt-id=1678078527  fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-2140\" src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Unable-to-Initialise-Server-Auto-Discovery.png\" alt=\"log phone messages\" width=\"505\" height=\"382\" srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:505\/h:382\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Unable-to-Initialise-Server-Auto-Discovery.png 505w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:227\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Unable-to-Initialise-Server-Auto-Discovery.png 300w\" sizes=\"(max-width: 505px) 100vw, 505px\" \/><\/a>If this happens to you, check your anti-virus software on your Server and Workstations.\u00c2\u00a0 Although PhonePad automatically creates the necessary firewall rules for the Windows Firewall, anti-virus software often ignores these settings.\u00c2\u00a0 You may need to allow the PhonePad Workstation and Server software to access UDP and\/or port 15350.\u00c2\u00a0 Your router may also be blocking the UDP protocol or port 15350.<\/p>\n<p>If you are unable to resolve this, there are a couple of other options you can use to connect.<\/p>\n<h2>Disable Auto-Discovery<\/h2>\n<p>Open <strong>Control Center<\/strong> on the Server or Host PC to check the <strong>Server IP Address<\/strong>.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Control-Center.png\"><img data-opt-id=1659972421  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Control-Center.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2142\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone message\" width=\"559\" height=\"459\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:559\/h:459\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Control-Center.png 559w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:246\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Control-Center.png 300w\" \/><\/a>Make a note of the IP Address.\u00c2\u00a0 Tip: If you double-click on the IP Address it will be copied to the Windows clipboard.<\/p>\n<p>On your workstation, open <strong>Workstation Config<\/strong>.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Disable-Auto-Discovery.png\"><img data-opt-id=787196888  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Disable-Auto-Discovery.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2143\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"521\" height=\"486\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:521\/h:486\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Disable-Auto-Discovery.png 521w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:280\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Disable-Auto-Discovery.png 300w\" \/><\/a>Select <strong>Disable Auto-Discovery of Server<\/strong> and enter the IP Address under <strong>Server IP Address<\/strong>, and then click <strong>Save<\/strong>.<\/p>\n<p>When you start PhonePad, it will show that the IP Address is overridden.<\/p>\n<h2><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery-Disabled.png\"><img data-opt-id=2119227728  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery-Disabled.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2145\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"505\" height=\"382\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:505\/h:382\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery-Disabled.png 505w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:227\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Auto-Discovery-Disabled.png 300w\" \/><\/a>Server Access Key<\/h2>\n<p>Open <strong>Control Center<\/strong> on the Server or Host PC, select <strong>PhonePad Server<\/strong>, and click the <strong>Settings<\/strong> button.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings.png\"><img data-opt-id=956752992  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2146\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"559\" height=\"459\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:559\/h:459\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings.png 559w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:246\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings.png 300w\" \/><\/a>When the <strong>Server Settings<\/strong> screen is displayed, you will need to create a <strong>Server Access Key<\/strong>.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings-Screen.png\"><img data-opt-id=1027227161  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings-Screen.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2147\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"470\" height=\"418\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:470\/h:418\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings-Screen.png 470w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:267\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Settings-Screen.png 300w\" \/><\/a>Click the button with the green padlock to create the <strong>Server Access Key<\/strong>.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Access-Key-1.png\"><img data-opt-id=1180818529  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Access-Key-1.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2155\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"470\" height=\"418\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:470\/h:418\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Access-Key-1.png 470w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:267\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Server-Access-Key-1.png 300w\" \/><\/a>Copy the <strong>Server Access Key<\/strong> by clicking the <strong>Copy<\/strong> button (next to the button with the green padlock).<\/p>\n<p>The <strong>Server Access Key<\/strong> needs to be registered.\u00c2\u00a0 Click the <strong>Register<\/strong> button.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Registered.png\"><img data-opt-id=1372830810  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Registered.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2149\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"470\" height=\"418\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:470\/h:418\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Registered.png 470w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:267\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Registered.png 300w\" \/><\/a>On your workstation, open <strong>Workstation Config<\/strong>.\u00c2\u00a0 Select <strong>Use Server Access Key<\/strong> and enter the <strong>Server Access Key<\/strong> that you created, then click <strong>Save<\/strong>.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Workstation-Config-Server-Access-Key.png\"><img data-opt-id=945574143  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Workstation-Config-Server-Access-Key.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2150\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"521\" height=\"486\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:521\/h:486\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Workstation-Config-Server-Access-Key.png 521w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:280\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/Workstation-Config-Server-Access-Key.png 300w\" \/><\/a>When you start PhonePad, it will retrieve the Server IP Address using the <strong>Server Access Key<\/strong>.<\/p>\n<p><a href=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/PhonePad-Retrieved-Server-Access-Key.png\"><img data-opt-id=216905644  data-opt-src=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/PhonePad-Retrieved-Server-Access-Key.png\"  decoding=\"async\" class=\"aligncenter size-full wp-image-2152\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"log phone messages\" width=\"505\" height=\"382\" old-srcset=\"https:\/\/mld50qmdoq2m.i.optimole.com\/w:505\/h:382\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/PhonePad-Retrieved-Server-Access-Key.png 505w, https:\/\/mld50qmdoq2m.i.optimole.com\/w:300\/h:227\/q:mauto\/ig:avif\/https:\/\/cybercom-software.com\/blog\/wp-content\/uploads\/2020\/05\/PhonePad-Retrieved-Server-Access-Key.png 300w\" \/><\/a>Please note: This method uses the Internet to retrieve the IP Address from our web server.\u00c2\u00a0 The <strong>Server Access Key<\/strong> will only work on your network and is useless outside of your network, which means it can&#8217;t be used to access PhonePad from a workstation outside of your network (unless you are using a VPN).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>One of the great things about PhonePad is that you don&#8217;t need to configure the workstation software to connect to the PhonePad Server.\u00c2\u00a0 It does it all automatically using Server Auto-Discovery. When you start PhonePad, your PhonePad workstation software will send out a message asking if there are any PhonePad servers on the network.\u00c2\u00a0 The [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[48,7,97,8,15,5],"tags":[173,179,180,178,188,189,46,169,183,53,24,27,181,182,26,52,56,54,55,59,85,214,93,99,47,193,151,57,51],"class_list":["post-2138","post","type-post","status-publish","format-standard","category-articles","category-phonepad","category-phonepad-5","category-phonepad-tips","category-tutorials","category-whats-happening","tag-call-log","tag-call-logging","tag-call-logging-software","tag-call-logs","tag-crm","tag-customer-relationship-manager","tag-local-area-network","tag-log-phone-calls","tag-logging-phone-calls","tag-message-pad","tag-minor-update","tag-new-release","tag-phone-call-log","tag-phone-call-logs","tag-phone-log","tag-phone-log-software","tag-phone-message","tag-phone-message-pad","tag-phone-message-software","tag-phone-messages","tag-phone-pad","tag-phone-slips","tag-phonepad","tag-phonepad-5","tag-phonepad-on-your-lan","tag-phoneslips","tag-portcheck","tag-telephone-message","tag-telephone-message-software"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/posts\/2138","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/comments?post=2138"}],"version-history":[{"count":8,"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/posts\/2138\/revisions"}],"predecessor-version":[{"id":2164,"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/posts\/2138\/revisions\/2164"}],"wp:attachment":[{"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/media?parent=2138"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/categories?post=2138"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cybercom-software.com\/blog\/wp-json\/wp\/v2\/tags?post=2138"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}